Command/Response Formats 115
Commands
TLT : Tiltmeter Set-up
$PASHQ, TLT,c
Query tiltmeter setup, where c is the optional output port and is not required to direct
the response to the current port.
Response message:
TILTMETER PARAMETERS SETTINGS
PRTA:OFF INIT_STR:NO TRIG_CMD:*0100XY INTVL:0001
PRTB:OFF INIT_STR:NO TRIG_CMD:*0100XY INTVL:0001
PRTC:OFF INIT_STR:NO TRIG_CMD:*0100XY INTVL:0001
PRTD:OFF INIT_STR:NO TRIG_CMD:*0100XY INTVL:0001
TLT,CMD: Tiltmeter Trigger String
$PASHS, TLT,CMD,c,s
Set tiltmeter trigger string, where c is the output port and s is the trigger string.
Example: set *9900XY to the TLT CMD field.
$PASHS,TLT,CMD,C,9900XY <enter>
TLT,INIT : Tiltmeter Initialization
$PASHS, TLT,INIT,
c,s
Set tiltmeter initialization string.
Table 6.50: TLT,CMD Message Structure
Parameters Description Range
c Serial port connected to the tiltmeter A - D
s trigger string of the tiltmeter excluding the starting ’*’ sign Limited to 20
alphanumeric
characters
Table 6.51: TLT,INIT Message Structure
Parameters Description Range
c Serial port connected to the tiltmeter A - D
s initialization string of the tiltmeter excluding the starting *’ sign Limited to 20
alphanumeric
characters