216 Z-Family Technical Reference Manual
UBP: Use Base Position
$PASHS,CPD,UBP,d1
This command selects the base position to use in ROVER mode, where d1 indicates
the desired base position. This command is relevant for ROVER mode only. Default
is 1.
Example: Use entered base station position.
$PASHS,CPD,UBP,0 <enter>
Table 6.151: CPD,UBP Parameter Table
Parameter Description Range Default
d1 Base position to use:
0 = Use entered base position
1 = Use transmitted base position
0,1 1