226 Z-Family Technical Reference Manual
-1190000.0,352000.0,2000000,500000 <enter>
Example: Set datum to grid transformation parameters.
$PASHS,UDG,LC83,637 8240,297.323,121.4,18.9,0,0,0,1.5 <enter>
$PASHQ,UDG,c
Associated query command where c is the optional output port and is not required to
direct the response message to the current communication port.
Example: Query datum to grid transformation parameters to port C
$PASHQ,UDG,C <enter>
$PASHR,UDG
The response is in the format:
$PASHR,UDG,s1,d2,f3,f4,f5,f6,f7,f8,f9,f10,f11,f12,f13*cc <enter>
where the fields (and the number of them) are defined in the above tables and depend
on the type of map projection selected.
Vue de la page 245